Bioanalytical Accuracy & Precision

%RE · %CV · run- and level-wise QC summary

Transparent modelExample dataLocal processingReview methodology →
ADVANCED ANALYSIS · RUO

Bioanalytical Accuracy & Precision

%RE · %CV · run- and level-wise QC summary

Calculated locally in this browser

Column order: run, qc_level, nominal, measured

Editable data table
runqc_levelnominalmeasured
Paste CSV / TSV

Analysis result

Measurements8
Runs2
Mean absolute %RE2.297%
RunQC levelNominalNMean measured%RE%CV
1LQC1029.85-1.56.461
1HQC80280.40.52.99
2LQC1029.95-0.52.132
2HQC80280.350.43751.496

Acceptance criteria depend on the validated method, matrix, analyte and applicable guidance. This summary does not declare regulatory acceptance.

Research use only. Validate raw data, exclusions and interpretation against the approved analysis plan.

INPUT FORMAT

Data requirements

Enter run, QC level, positive nominal concentration and measured value.

run, qc_level, nominal, measured
INTERPRETATION

Review before reporting

Research use only. Validate raw data, exclusions and interpretation against the approved analysis plan.

Check raw observations, excluded rows, model assumptions and study-specific acceptance criteria before using the result.