IC50 / EC50 4PL 計算機

4PL用量反応 · IC50/EC50 · Hill勾配 · R²

Transparent modelExample dataLocal processingReview methodology →
ADVANCED ANALYSIS · RUO

IC50 / EC50 4PL 計算機

4PL用量反応 · IC50/EC50 · Hill勾配 · R²

計算はこのブラウザ内で実行されます

列の順序: 濃度, 反応値

編集可能な表
concentrationresponse
CSV / TSV を貼り付け

単位換算: 1 µM = 1 µM

解析結果

IC50 / EC500.3689 µM
Hill勾配-0.9405
下限 / 上限2.722 / 99.7
R²0.9996
有効行7
Loading chart…

研究用途のみ。原データと解析計画で検証してください。

INPUT FORMAT

Data requirements

4行以上の有効データを入力してください。濃度は0より大きく、反応値は数値である必要があります。

濃度, 反応値
INTERPRETATION

Review before reporting

研究用途のみ。原データと解析計画で検証してください。

Check raw observations, excluded rows, model assumptions and study-specific acceptance criteria before using the result.

METHOD

Transparent analysis

Inputs are processed locally in your browser. Review the calculation policy, limitations and verification approach before reporting a result.

Read the methodology →
EVIDENCE & REVIEW

A result you can audit.

Reviewed 12 August 20264-parameter logistic workflow review complete
01

Implementation check

The workflow preserves raw rows, shows the fitted curve and reports model parameters so users can judge whether the observed concentrations bracket the response midpoint.

02

Interpretation boundary

An estimated IC50 is model- and assay-dependent. Sparse plateaus, constrained parameters, outliers or an unbracketed midpoint can produce a precise-looking but weak estimate.

REFERENCE VALIDATION CASE

Bracketed synthetic 4PL midpoint

Noise-free values generated from the same four-parameter logistic form used by the calculator.

Inputs
  • Bottom 0, top 100
  • Hill slope 1
  • Synthetic midpoint at 1 µM
  • Concentrations on both sides of 1 µM
Expected result
  • Fitted midpoint approximately 1 µM
  • Top and bottom approach 100 and 0
  • R² greater than 0.999 for noise-free data
CHECK IDLAB-VAL-006TOLERANCEMidpoint within 5%; R² > 0.999LAST RUN13 August 2026AUTOMATED CHECK4PL fit midpoint, plateau behavior and goodness of fit

Scope: A software regression check, not biological or assay validation.

Review and correction history

12 August 2026 · Internal implementation review

4-parameter logistic workflow review complete. Formula behavior, unit handling, limitations and linked references were checked internally.

Independent reviewer: Not yet published. A name, relevant qualification, date and exact scope will appear here only after a real review is completed.

Source-informed and internally checked; independent scientific or regulatory validation is not claimed. Research use only.