ELISA 4PL / 5PL 표준곡선

4PL/5PL 표준곡선 적합 · 미지시료 보간

Transparent modelExample dataLocal processingReview methodology →
ADVANCED ANALYSIS · RUO

ELISA 4PL / 5PL 표준곡선

4PL/5PL 표준곡선 적합 · 미지시료 보간

모든 계산은 이 브라우저에서 수행됩니다

열 순서: 표준물질 농도, OD

직접 편집 표
concentrationOD
CSV / TSV 붙여넣기

단위 변환: 1 µM = 1 µM

분석 결과

모델4PL
R²0.9999
미지시료 농도22.05 µM
희석배수10×
Loading chart…

연구용 도구입니다. 원자료, 제외 기준과 해석은 승인된 분석 계획에 따라 검증하세요.

INPUT FORMAT

Data requirements

4PL은 유효한 표준물질 4개 이상, 5PL은 5개 이상이 필요합니다. 농도는 0보다 커야 하고 OD는 숫자여야 합니다.

표준물질 농도, OD
INTERPRETATION

Review before reporting

연구용 도구입니다. 원자료, 제외 기준과 해석은 승인된 분석 계획에 따라 검증하세요.

Check raw observations, excluded rows, model assumptions and study-specific acceptance criteria before using the result.

METHOD

Transparent analysis

Inputs are processed locally in your browser. Review the calculation policy, limitations and verification approach before reporting a result.

Read the methodology →
EVIDENCE & REVIEW

A result you can audit.

Reviewed 12 August 20264PL/5PL calibration and inversion review complete
01

Implementation check

The analysis preserves standard observations, fits a selected logistic calibration model and flags unknowns that cannot be inverted to a supported concentration.

02

Interpretation boundary

Only report concentrations within a method-supported range. Curve fit alone does not establish calibrator acceptance, matrix suitability, dilution integrity, accuracy or precision.

REFERENCE VALIDATION CASE

Synthetic logistic calibration

Forward-generated response inverted with the same 4PL calibration model.

Inputs
  • Noise-free 4PL standards
  • Unknown response generated at 50 concentration units
  • Unknown inside the standard range
Expected result
  • 4PL fit reproduces the calibration trend
  • Interpolated unknown approximately 50
  • No out-of-range warning
CHECK IDLAB-VAL-007TOLERANCEBack-calculated concentration within 2%LAST RUN13 August 2026AUTOMATED CHECKLogistic calibration, inversion and in-range recovery

Scope: Does not replace run acceptance, matrix, accuracy or precision criteria.

Review and correction history

12 August 2026 · Internal implementation review

4PL/5PL calibration and inversion review complete. Formula behavior, unit handling, limitations and linked references were checked internally.

Independent reviewer: Not yet published. A name, relevant qualification, date and exact scope will appear here only after a real review is completed.

Source-informed and internally checked; independent scientific or regulatory validation is not claimed. Research use only.

TOSSORAMain site