ELISA 4PL / 5PL-Standardkurve

4PL/5PL-Standardkurve · Probeninterpolation

Lokale Berechnung in diesem Browser

Spaltenreihenfolge: Standardkonzentration, OD

Bearbeitbare Tabelle
concentrationOD
CSV / TSV einfügen

Umrechnung: 1 µM = 1 µM

Analyseergebnis

Modell4PL
R²0.9999
Unbekannte Konzentration22.05 µM
Verdünnung10×
Loading chart…

Nur für Forschungszwecke. Mit Rohdaten und Analyseplan validieren.

INPUT FORMAT

Data requirements

4PL benötigt mindestens 4 gültige Standards, 5PL mindestens 5. Konzentrationen müssen größer als 0 und OD-Werte numerisch sein.

Standardkonzentration, OD
INTERPRETATION

Review before reporting

Nur für Forschungszwecke. Mit Rohdaten und Analyseplan validieren.

Check raw observations, excluded rows, model assumptions and study-specific acceptance criteria before using the result.

METHOD

Transparent analysis

Inputs are processed locally in your browser. Review the calculation policy, limitations and verification approach before reporting a result.

Read the methodology →
EVIDENCE & REVIEW

A result you can audit.

Reviewed 12 August 20264PL/5PL calibration and inversion review complete
01

Implementation check

The analysis preserves standard observations, fits a selected logistic calibration model and flags unknowns that cannot be inverted to a supported concentration.

02

Interpretation boundary

Only report concentrations within a method-supported range. Curve fit alone does not establish calibrator acceptance, matrix suitability, dilution integrity, accuracy or precision.

REFERENCE VALIDATION CASE

Synthetic logistic calibration

Forward-generated response inverted with the same 4PL calibration model.

Inputs
  • Noise-free 4PL standards
  • Unknown response generated at 50 concentration units
  • Unknown inside the standard range
Expected result
  • 4PL fit reproduces the calibration trend
  • Interpolated unknown approximately 50
  • No out-of-range warning
CHECK IDLAB-VAL-007TOLERANCEBack-calculated concentration within 2%LAST RUN13 August 2026AUTOMATED CHECKLogistic calibration, inversion and in-range recovery

Scope: Does not replace run acceptance, matrix, accuracy or precision criteria.

Review and correction history

12 August 2026 · Internal implementation review

4PL/5PL calibration and inversion review complete. Formula behavior, unit handling, limitations and linked references were checked internally.

Independent reviewer: Not yet published. A name, relevant qualification, date and exact scope will appear here only after a real review is completed.

Source-informed and internally checked; independent scientific or regulatory validation is not claimed. Research use only.